> Automated Wind-protector/quick tube heater: 11s/18s.
> Innovative carrying case design: Swift deployment upon opening case, working table.
> Shock / dust / resistance: World's first 6-direction 30" drop proof in harsh conditions.
> Wide color LCD monitor: High resolution 4.7" monitor with better backlight.
> Powerful Li-ion battery: 110 splice / heating per full battery charge.
> Pre-installed instruction& user guide: operation guide, trouble shooting procedure.
| ITEM | SPECIFICATIONS |
|---|
| Applicable type of fibers | SMF(G.652/657), MMF(G.651), DSF(G.653), NZDSF(G.655) |
| Fiber count | Single to 12 |
| Cladding dia./ Sheathe dia | Single : 125 μm / 160μm to 3mm by fiber holder system Ribbon : 125um / Ribbon fiber thickness 0.25 to 0.4mm |
| Cleave length | 10mm to 13mm |
| Splice mode / heating mode | Total 100 splice modes / 30 heating modes |
| Typical splice loss | 0.05dB (SM), 0.02dB(MM), 0.08dB(DS) and 0.08dB(NZDS). |
| Splice time / tube heating time | Typical 11sec with SM FAST, 15sec with SM AUTO / Typical 18sec with FP-04(T) sleeve |
| Splice result storage | Last 2000 splices |
| Viewing methods / magnification | 2 axis CMOS camera with 4.73” color LCD. X / Y (35 - 90X magnification, automatically change depending on fiber count), or both X and Y simultaneously |
| Tension test | 1.96 to 2.25N |
| Applicable protection sleeve | 60mm, 40mm and Fujikura micro sleeves |
| No. of splice / heating per battery full charge*1 | Typical 110 cycles with BTR-09 |
| Electrode life | 1500 splices |
| Size / weight | 146W x 159D x 150H (mm) / 2.5kg (including battery) |
| Operating condition | Altitude : 0 to 3,660m above sea level, Wind : 15m/sec Temperature : -10 to 50deg C, Humidity : 0 to 95%RH, non-dew |
| Resistance tests*2 | Shock : 30in all surface drop Dust : Exposure to dust (0.1 to 500μm dia Alumina Silicate) IP5X Rain : H=10mm/hr for 10min IPX2 |
| Other features | PC software upgrade / data management |
| Terminals | USB 2.0 (Mini-B type) connector for PC communication. 6-pin Mini-DIN connector for HJS-02 or HJS-03 power supply. |
*1:one(1) splicing and heating cycle per two(2) min. under room temperature condition.
*2:Carried out in Fujikura labs in Japan. The shock, dust and rain resistance test do not guarantee the product will not be damaged under these conditions.
Fujikura Fusion Splicer: FSM-70R, ribbon, standard accessories.
|